本目錄是上海蘇特(te)電(dian)氣(qi)有限公(gong)司為您精心選(xuan)購的:
TFD-18發(fa)電(dian)機定子手包絕緣測量(liang)桿
常規(gui)的(de)(de)預防性試(shi)(shi)驗(yan)一般很難發(fa)現汽輪發(fa)電(dian)機(ji)(ji)(ji)(ji)內(nei)冷定(ding)子線(xian)(xian)端(duan)(duan)部(bu)(bu)(bu)(bu)絕緣(yuan)的(de)(de)缺(que)陷。直流加(jia)壓表(biao)面電(dian)位(wei)法試(shi)(shi)驗(yan)能有(you)效地找出(chu)定(ding)子線(xian)(xian)圈端(duan)(duan)部(bu)(bu)(bu)(bu)的(de)(de)絕緣(yuan)缺(que)陷。定(ding)子端(duan)(duan)部(bu)(bu)(bu)(bu)相間短路(lu)故障(zhang),造成很大(da)的(de)(de)經濟(ji)損失,為此(ci),電(dian)力工(gong)業部(bu)(bu)(bu)(bu)和機(ji)(ji)(ji)(ji)械(xie)工(gong)業部(bu)(bu)(bu)(bu)下達了(le)(le)安(an)生技(1994)86號文(wen)件,規(gui)定(ding)了(le)(le)發(fa)電(dian)機(ji)(ji)(ji)(ji)端(duan)(duan)部(bu)(bu)(bu)(bu)手(shou)包絕緣(yuan)測量試(shi)(shi)驗(yan)為發(fa)電(dian)機(ji)(ji)(ji)(ji)的(de)(de)重要(yao)試(shi)(shi)驗(yan)項目之一,TFD-18發(fa)電(dian)機(ji)(ji)(ji)(ji)定(ding)子端(duan)(duan)部(bu)(bu)(bu)(bu)表(biao)面電(dian)位(wei)測量桿是*86號文(wen)件精(jing)神(shen)的(de)(de)高(gao)科(ke)技產品,它(ta)的(de)(de)投入使用,極大(da)地提(ti)高(gao)了(le)(le)發(fa)電(dian)機(ji)(ji)(ji)(ji)的(de)(de)檢修效率。
別稱:電位差計,發電機電位差計,發電機表面電位測試儀,發電機電位外移測試儀,發電機定子手包絕緣測試儀,發電機表面電位測量桿,發電機定子線圈端部表面電位測量儀. 發電機電位外移檢測儀,發電機定子端部絕緣測試儀,發電機手包絕緣測量桿
發(fa)電(dian)(dian)機定(ding)子(zi)(zi)端(duan)(duan)部(bu)絕(jue)緣測(ce)試(shi)(shi)儀,是利(li)用表面電(dian)(dian)位(wei)法(又稱(cheng)電(dian)(dian)位(wei)外移法)檢測(ce)發(fa)電(dian)(dian)機定(ding)子(zi)(zi)線(xian)(xian)棒(bang)絕(jue)緣缺陷(xian)(xian)的絕(jue)緣測(ce)試(shi)(shi)方法。通過檢測(ce)定(ding)子(zi)(zi)端(duan)(duan)部(bu)手包絕(jue)緣的密實性及相對(dui)絕(jue)緣強(qiang)度。它可(ke)以彌補發(fa)電(dian)(dian)機定(ding)子(zi)(zi)繞組交、直流耐(nai)壓(ya)試(shi)(shi)驗所發(fa)現不了的端(duan)(duan)部(bu)絕(jue)緣缺陷(xian)(xian)的不足。可(ke)以發(fa)現引線(xian)(xian)包絕(jue)緣不良(liang),線(xian)(xian)圈鼻端(duan)(duan)絕(jue)緣包扎缺陷(xian)(xian),絕(jue)緣盒填(tian)充泥填(tian)充不滿,綁扎滌玻繩(sheng)固化(hua)不良(liang)及端(duan)(duan)部(bu)接頭處定(ding)子(zi)(zi)空(kong)心銅線(xian)(xian)焊接質(zhi)量不良(liang)造成的滲透等缺陷(xian)(xian)。發(fa)電(dian)(dian)機定(ding)子(zi)(zi)線(xian)(xian)圈端(duan)(duan)部(bu)表面電(dian)(dian)位(wei)測(ce)量是一(yi)項(xiang)新的試(shi)(shi)驗項(xiang)目,線(xian)(xian)圈端(duan)(duan)部(bu)起到(dao)了監督作(zuo)用,進一(yi)步提高了發(fa)電(dian)(dian)機安(an)全運(yun)行(xing)的可(ke)靠(kao)性。
技術參數:
1.輸入電(dian)阻100M
2.測試電(dian)壓:DC0-30KV
3.電壓(ya)精度:1.0%
試驗方法:
1 試(shi)驗標(biao)準(zhun)發電機定(ding)子(zi)線圈端(duan)部絕緣判斷標(biao)準(zhun),是加2 倍的額(e)定(ding)電壓,漏泄電流不大于1微(wei)安
2 試驗儀器直流高壓發生裝置
3 測試原理將直流電壓加在定子線棒正常時由于線棒絕緣的體積電阻Ρρ 遠遠大于表面電阻ρσ , 對地電壓很低, 若某一線棒絕緣存在缺陷,它
的電壓(ya)分布將發生明顯的變化,絕(jue)緣(yuan)存在缺陷時, Ρρ 減小,絕(jue)緣(yuan)壓(ya)降(jiang)也降(jiang)低,致使缺陷部位對地電壓(ya)增高。
4 測試方法將繞組三相引出線用導線短路連接,直流高壓發生器加2倍電壓
,用(yong)發(fa)電(dian)機(ji)電(dian)位外移試驗儀測試電(dian)壓和電(dian)流
5.發(fa)電機(ji)電位外移試驗(yan)儀接線(xian)圖
6.尾棒的地線(xian)(xian)一(yi)定與高壓發生裝置的地線(xian)(xian)接在一(yi)起。
注意事項:
1、錫(xi)(xi)箔紙纏(chan)包端部時(shi),一定(ding)要包裹(guo)緊密,否則錫(xi)(xi)箔紙和絕緣表(biao)面會(hui)構(gou)成電(dian)容(rong),測量桿(gan)接觸時(shi)會(hui)有較(jiao)大的(de)放電(dian)電(dian)流,造(zao)成誤判斷。
2、端部包裹時分為線棒(bang)側和引水管側,間隔大于3厘米,電位高(gao)時便于查找(zhao)是哪一側的問題,其實zui主要的點是根(gen)部和錐部,中間部位測量意義不大。
3、測量桿(gan)串(chuan)接的微(wei)安表用(yong)數字式微(wei)安表,即便于(yu)讀數又可電流大(da)時(shi)保護表記。
4、端部(bu)接(jie)頭(tou)因為在(zai)在(zai)機殼下部(bu),不易測量,提前用引線引出。
5、zui重要的(de)是記(ji)正確異常(chang)槽號,避免(mian)張冠李戴,切記(ji)切記(ji)!
6、發電機不通水的情況下進(jin)行試驗,要求先將(jiang)定子冷卻水*吹(chui)凈。