產品型號:Z-V型 雷電計數器校驗儀
一. 技術參數
1. 電壓:DC900V1200V 1600V三(san)檔
2. 放電電流>100A/10US
二. 使用方法
.1.使(shi)(shi)用(yong)前先充電(dian)(dian)(dian),為(wei)確保(bao)充電(dian)(dian)(dian)效果和延長電(dian)(dian)(dian)池使(shi)(shi)用(yong)壽命,需(xu)使(shi)(shi)用(yong)專配的充電(dian)(dian)(dian)器.空電(dian)(dian)(dian)池到充滿需(xu)3-4小時,充電(dian)(dian)(dian)器上紅燈(deng)亮表(biao)示(shi)正在充電(dian)(dian)(dian);綠燈(deng)表(biao)示(shi)充電(dian)(dian)(dian)完(wan)畢.使(shi)(shi)用(yong)前在尾端插接(jie)好所附地線插頭,地線夾(jia)接(jie)大(da)地.
2.根據計數(shu)器安裝高度,適當拉(la)出伸(shen)縮(suo)放電桿.
3.按下紅色按鈕,接通(tong)高壓(ya)約1秒(miao)鐘,指示燈(deng)亮(微(wei)閃),即可輕輕點擊計數(shu)器(qi)與(yu)避雷器(qi)的連接端進行測試.
4.每(mei)次(ci)點(dian)擊后,放電桿端(duan)頭應(ying)離開計數器.若需重復測試,可不必松開按(an)鈕,約過,1-2秒鐘指示燈再次(ci)閃爍(shuo)時,即(ji)可再次(ci)點(dian)擊測試.
5.連續測試會導致檢(jian)驗(yan)儀發熱,請注(zhu)意適當(dang)間(jian)歇時間(jian).
6.如按(an)下按(an)鈕3秒鐘以(yi)上指(zhi)示(shi)燈仍未閃亮,則(ze)表示(shi)需(xu)對電池進行充電.
7.校驗儀請(qing)勿隨(sui)意(yi)拆卸.如電池容(rong)量明顯下降或(huo)充電效率過低,則(ze)需要換,請(qing)向(xiang)本(ben)公(gong)司購買電池組.
注意:指示燈(deng)亮(微閃)時身體的任何部(bu)位(wei)均不能碰觸電極部(bu)分,否則有電擊(ji)危險.
更多產品,詳細說明請登陸:上海蘇特電氣有限公司